Pro Energy Generators

Providing Power Solutions To all Industries

15 – 25 KW Diesel Generator

SpecificationsGenerator – Single
TypeWheeled
Output15 – 25 KW
FuelDiesel
RPM1800
Frequency60HZ
Voltage- Three Phase208 – 480V Switchable
Voltage- Single Phase120 – 277V Switchable
Single Phase (120V Amps)55.6A (4 wire) – 60Ax2 (zigzag)
Single Phase (120-240V Amps)27.8A (4 wire) – 60A (zigzag)
Three Phase (208-240V Amps)60A
Three Phase (460-480V Amps)30A
Decibel dB(A) – Full load at 7 m (23ft)56
Fuel Tank Capacity – Litres (Imp Gal)158 (35)
Fuel Consumption at 100% load Litres (Imp Gal)per hour5.47 (1.20)
75% load – Litres (Imp Gal) per hour3.99 (0.88)
50% load – Litres (Imp Gal) per hour2.81 (0.62)
25% load – Litres (Imp Gal) per hour1.7 (0.37)
L x W x H Cm (In) – unit w/o trailer179 x 79 x 126 (5’10” x 2’7″ x 4’2″)
Net Weight Kg (Lb) – unit w/o trailer835 (1840)
L x W x H Cm (In) – unit w/ trailer284 x 140 x 152 (9’4″ x 4’7″ x 5′)
Net Weight Kg (Lb) -unit w/ trailer1742 (3840)
NEMA Rating3 – Outdoor Use
 

30 – 45 KW Wheeled Diesel Generator

SpecificationsGenerator – Single
TypeWheeled
Output30 – 45 KW
FuelDiesel
RPM1800
Frequency60HZ
Voltage- Three Phase208 – 480V Switchable
Voltage- Single Phase120 – 277V Switchable
Single Phase (120V Amps)100A (4 wire) / 108Ax2 (zigzag)
Single Phase (120-240V Amps)50A (4 wire) / 108A (zigzag)
Three Phase (208-240V Amps)108A
Three Phase (460-480V Amps)54A
Decibel dB(A) – Full load at 7 m (23ft)57
Fuel Tank Capacity – Litres (Imp Gal)359 (79)
Fuel Consumption at 100% load Litres (Imp Gal)per hour9.84 (2.16)
75% load – Litres (Imp Gal) per hour7.47 (1.64)
50% load – Litres (Imp Gal) per hour5.42 (1.19)
25% load – Litres (Imp Gal) per hour3.3 (0.73)
L x W x H Cm (Ft) – unit w/o trailer209 x 95 x 155 (6’10” x 3’1″ x 5’1″)
Net Weight Kg (Lb) – unit w/o trailer1334 (2940)
L x W x H Cm (Ft) – unit w/ trailer371 x 165 x 201 (12′ x 5’4″ x 6’6″)
Net Weight Kg (Lb) -unit w/ trailer2468 (5440)
NEMA Rating3 – Outdoor Use

30 – 45 KW Skid Type Diesel Generator

SpecificationsGenerator – Single
TypeSkidded
Output30 – 45 KW
FuelDiesel
RPM1800
Frequency60HZ
Voltage- Three Phase208 – 480V Switchable
Voltage- Single Phase120 – 277V Switchable
Single Phase (120V Amps)100A (4 wire) / 108Ax2 (zigzag)
Single Phase (120-240V Amps)50A (4 wire) / 108A (zigzag)
Three Phase (208-240V Amps)108A
Three Phase (460-480V Amps)54A
Decibel dB(A) – Full load at 7 m (23ft)57
Fuel Tank Capacity – Litres (Imp Gal)300 (66)
Fuel Consumption at 100% load Litres (Imp Gal)per hour9.84 (2.16)
75% load – Litres (Imp Gal) per hour7.47 (1.64)
50% load – Litres (Imp Gal) per hour5.42 (1.19)
25% load – Litres (Imp Gal) per hour3.3 (0.73)
L x W x H Cm (In) – unit w/o skid209 x 95 x 155 (82 x 37 x 61)
Net Weight Kg (Lb) – unit w/o skid1334 (2940)
L x W x H Cm (In) – unit w/ skid371 x 165 x 201 (146 x 65 x 79)
Net Weight Kg (Lb) -unit w/ skid2468 (5440)
NEMA Rating3 – Outdoor Use
 

60 – 75 KW Diesel Generator

SpecificationsGenerator – Single
TypeWheeled
Output60 – 75 KW
FuelDiesel
RPM1800
Frequency60HZ
Voltage- Three Phase208 – 480V Switchable
Voltage- Single Phase120 – 277V Switchable
Single Phase (120V Amps)155.5A (4 wire) / 168Ax2 (zigzag)
Single Phase (120-240V Amps)77.8A (4 wire) / 168A (zigzag)
Three Phase (208-240V Amps)168A
Three Phase (460-480V Amps)84A
Decibel dB(A) – Full load at 7 m (23ft)60
Fuel Tank Capacity – Litres (Imp Gal)480 (106)
Fuel Consumption at 100% load Litres (Imp Gal)per hour18.9 (4.16)
75% load – Litres (Imp Gal) per hour13.4 (2.95)
50% load – Litres (Imp Gal) per hour8.9 (1.96)
25% load – Litres (Imp Gal) per hour5.9 (1.30)
L x W x H Cm (In) – unit w/o trailer277 x 124 x 180 (109 x 49 x 71)
Net Weight Kg (Lb) – unit w/o trailer2127 (4690)
L x W x H Cm (In) – unit w/ trailer434 x 183 x 213 (171 x 72 x 84)
Net Weight Kg (Lb) -unit w/ trailer3443 (7590)
NEMA Rating3 – Outdoor Use

110 – 125 KW Skid Type Diesel Generator

SpecificationsGenerator – Single
TypeSkidded
Output110 – 125 KW
FuelDiesel
RPM1800
Frequency60HZ
Voltage- Three Phase208 – 480V Switchable
Voltage- Single Phase120 – 277V Switchable
Single Phase (120V Amps)277.8A (4 wire) / 301Ax2 (zigzag)
Single Phase (120-240V Amps)138.9A (4 wire) / 301A (zigzag)
Three Phase (208-240V Amps)301A
Three Phase (460-480V Amps)150A
Decibel dB(A) – Full load at 7 m (23ft)62
Fuel Tank Capacity – Litres (Imp Gal)640 (141)
Fuel Consumption at 100% load Litres (Imp Gal)per hour29 (6.38)
75% load – Litres (Imp Gal) per hour21.9 (4.82)
50% load – Litres (Imp Gal) per hour14.5 (3.19)
25% load – Litres (Imp Gal) per hour9.3 (2.05)
L x W x H Cm (In) – unit w/o skid305 x 124 x 186 (120 x 49 x 73)
Net Weight Kg (Lb) – unit w/o skid2735 (6031)
L x W x H Cm (In) – unit w/ skid488 x 203 x 229 (192 x 80 x 90)
Net Weight Kg (Lb) -unit w/ skid4459 (9831)
NEMA Rating3 – Outdoor Use

110 – 125 KW Wheeled Diesel Generator

SpecificationsGenerator – Single
TypeWheeled
Output110 – 125 KW
FuelDiesel
RPM1800
Frequency60HZ
Voltage- Three Phase208 – 480V Switchable
Voltage- Single Phase120 – 277V Switchable
Single Phase (120V Amps)277.8A (4 wire) / 301Ax2 (zigzag)
Single Phase (120-240V Amps)138.9A (4 wire) / 301A (zigzag)
Three Phase (208-240V Amps)301A
Three Phase (460-480V Amps)150A
Decibel dB(A) – Full load at 7 m (23ft)62
Fuel Tank Capacity – Litres (Imp Gal)640 (141)
Fuel Consumption at 100% load Litres (Imp Gal)per hour29 (6.38)
75% load – Litres (Imp Gal) per hour21.9 (4.82)
50% load – Litres (Imp Gal) per hour14.5 (3.19)
25% load – Litres (Imp Gal) per hour9.3 (2.05)
L x W x H Cm (In) – unit w/o trailer305 x 124 x 186 (120 x 49 x 73)
Net Weight Kg (Lb) – unit w/o trailer2735 (6031)
L x W x H Cm (In) – unit w/ trailer488 x 203 x 229 (192 x 80 x 90)
Net Weight Kg (Lb) -unit w/ trailer4459 (9831)
NEMA Rating3 – Outdoor Use

130 – 150 KW Wheeled Diesel Generator

SpecificationsGenerator – Single
TypeWheeled
Output130 – 150 KW
FuelDiesel
RPM1800
Frequency60HZ
Voltage- Three Phase208 – 480V Switchable
Voltage- Single Phase120 – 277V Switchable
Single Phase (120V Amps)333.3A (4 wire) / 361Ax2 (zigzag)
Single Phase (120-240V Amps)166.7A(4 wire) / 361A(zigzag)
Three Phase (208-240V Amps)361A
Three Phase (460-480V Amps)180A
Decibel dB(A) – Full load at 7 m (23ft)63
Fuel Tank Capacity – Litres (Imp Gal)810(178)
Fuel Consumption at 100% load Litres (Imp Gal)per hour34.8(7.65)
75% load – Litres (Imp Gal) per hour26.1(5.74)
50% load – Litres (Imp Gal) per hour17.9(3.94)
25% load – Litres (Imp Gal) per hour11(2.42)
L x W x H Cm (In) – unit w/o trailer325 x 124 x 191 (128 x 49 x 75)
Net Weight Kg (Lb) – unit w/o trailer3035 (6690)
L x W x H Cm (In) – unit w/ trailer488 x 208 x 236 (192 x 82 x 93)
Net Weight Kg (Lb) -unit w/ trailer4758 (10490)
NEMA Rating3 – Outdoor Use

130 – 150 KW Twin Pak Diesel Generator

SpecificationsGenerator – Twin
TypeSkidded
Output130 – 150 KW
FuelDiesel
RPM1800
Frequency60HZ
Voltage- Three Phase208 – 480V Switchable
Voltage- Single Phase120 – 277V Switchable
Single Phase (120V Amps)N/A
Single Phase (120-240V Amps)12-30A / 4 Pole Twist Lock
Three Phase (208-240V Amps)2-30A / 2-60A / 2-100A 4 Wire / 4 Pole Crouse Hines
Three Phase (460-480V Amps)2-30A / 2-60A / 2-100A 3 Wire / 4 Pole Crouse Hines
Decibel dB(A) – Full load at 7 m (23ft)63
Fuel Tank Capacity – Litres (Imp Gal)2270 (500)
Fuel Consumption at 100% load Litres (Imp Gal)per hour34.8 (7.65)
75% load – Litres (Imp Gal) per hour26.1 (5.74)
50% load – Litres (Imp Gal) per hour17.9 (3.94)
25% load – Litres (Imp Gal) per hour11 (2.42)
L x W x H Cm (In) – unit w/o skid325 x 124 x 191 (128 x 49 x 75)
Net Weight Kg (Lb) – unit w/o skid3035 (6690)
L x W x H Cm (In) – unit w/ skid488 x 208 x 236 (192 x 82 x 93)
Net Weight Kg (Lb) -unit w/ skid12,727 (28,000)
NEMA Rating3 – Outdoor Use

130 – 150 KW Skid Type Diesel Generator

SpecificationsGenerator – Single
TypeSkidded
Output130 – 150 KW
FuelDiesel
RPM1800
Frequency60HZ
Voltage- Three Phase208 – 480V Switchable
Voltage- Single Phase120 – 277V Switchable
Single Phase (120V Amps)333.3A (4 wire) / 361Ax2 (zigzag)
Single Phase (120-240V Amps)166.7A (4 wire) / 361A (zigzag)
Three Phase (208-240V Amps)361A
Three Phase (460-480V Amps)180A
Decibel dB(A) – Full load at 7 m (23ft)63
Fuel Tank Capacity – Litres (Imp Gal)973 (214)
Fuel Consumption at 100% load Litres (Imp Gal)per hour34.8 (7.65)
75% load – Litres (Imp Gal) per hour26.1 (5.74)
50% load – Litres (Imp Gal) per hour17.9 (3.94)
25% load – Litres (Imp Gal) per hour11 (2.42)
L x W x H Cm (Ft) – unit w/o skid325 x 124 x 191 (12’8″ x 4’1″ x 6’3″)
Net Weight Kg (Lb) – unit w/o skid3035 (6690)
L x W x H Cm (Ft) – unit w/ skid488 x 152 x 214 (16′ x 5’1″ x 7’4″)
Net Weight Kg (Lb) -unit w/ skid4758 (10490)
NEMA Rating3 – Outdoor Use

175 – 200 KW Diesel Generator

SpecificationsGenerator – Single
TypeWheeled
Output175 – 200 KW
FuelDiesel
RPM1800
Frequency60HZ
Voltage- Three Phase208 – 480V Switchable
Voltage- Single Phase120 – 277V Switchable
Single Phase (120V Amps)489.9A (4 wire)
Single Phase (120-240V Amps)244.4A (4 wire)
Three Phase (208-240V Amps)529A
Three Phase (460-480V Amps)265A
Decibel dB(A) – Full load at 7 m (23ft)68
Fuel Tank Capacity – Litres (Imp Gal)454 (100)
Fuel Consumption at 100% load Litres (Imp Gal)per hour51.6 (11.35)
75% load – Litres (Imp Gal) per hour39.5 (8.69)
50% load – Litres (Imp Gal) per hour29.3 (6.45)
25% load – Litres (Imp Gal) per hour17.2 (3.78)
L x W x H Cm (Ft) – unit w/o trailer355 x 124 x 170 (11’6″ x 4’1″ x 5’7″)
Net Weight Kg (Lb) – unit w/o trailer3182 (7016)
L x W x H Cm (In) – unit w/ trailer518 x 198 x 229 (16′ x 5’1″ x 6’7″)
(wet) Net Weight Kg (Lb)5042 (11116)
NEMA Rating3 Outdoor Use

200 – 220 KW Diesel Generator

SpecificationsGenerator – Single
TypeSkidded
Output200 – 220 KW
FuelDiesel
RPM1800
Frequency60HZ
Voltage- Three Phase208 – 480V Switchable
Voltage- Single Phase120 – 277V Switchable
Single Phase (120V Amps)555.5A (4 wire)
Single Phase (120-240V Amps)277.7A (4 wire)
Three Phase (208-240V Amps)601A
Three Phase (460-480V Amps)301A
Decibel dB(A) – Full load at 7 m (23ft)68
Fuel Tank Capacity – Litres (Imp Gal)454 (100)
Fuel Consumption at 100% load Litres (Imp Gal)per hour55.8 (12.27)
75% load – Litres (Imp Gal) per hour41.2 (9.06)
50% load – Litres (Imp Gal) per hour28.5 (6.27)
25% load – Litres (Imp Gal) per hour16.6 (3.65)
L x W x H Cm (Ft) – unit w/o skid375 x 140 x 180 (12’2″ x 4’7″ x 5’11”)
Net Weight Kg (Lb) – unit w/o skid4220 (9305)
L x W x H Cm (Ft) – unit w/ skid544 x 198 x 267 (16′ x 5’1″ x 6’7″)
Net Weight Kg (Lb) -unit w/ skid6398 (14105)
NEMA Rating3 Outdoor Use

250 – 300 KW Diesel Generator

SpecificationsGenerator – Single
TypeSkidded
Output250 – 300 KW
FuelDiesel
RPM1800
Frequency60HZ
Voltage- Three Phase208 – 480V Switchable
Voltage- Single Phase120 – 277V Switchable
Single Phase (120V Amps)555.5A (4 wire)
Single Phase (120-240V Amps)277.7A (4 wire)
Three Phase (208-240V Amps)601A
Three Phase (460-480V Amps)301A
Decibel dB(A) – Full load at 7 m (23ft)68
Fuel Tank Capacity – Litres (Imp Gal)460 (101)
Fuel Consumption at 100% load Litres (Imp Gal)per hour55.8 (12.27)
75% load – Litres (Imp Gal) per hour41.2 (9.06)
50% load – Litres (Imp Gal) per hour28.5 (6.27)
25% load – Litres (Imp Gal) per hour16.6 (3.65)
L x W x H Cm (In) – unit w/o skid375 x 140 x 180 (146 x 55 x 71)
Net Weight Kg (Lb) – unit w/o skid4220 (9305)
L x W x H Cm (In) – unit w/ skid544 x 198 x 267 (214 x 78 x 105)
Net Weight Kg (Lb) -unit w/ skid6398 (14105)
NEMA Rating3 Outdoor Use

300 – 400 KW Diesel Generator

SpecificationsGenerator – Single
TypeWheeled
Output300 – 400 KW
FuelDiesel
RPM1800
Frequency60HZ
Voltage- Three Phase208 – 480V Switchable
Voltage- Single Phase120 – 277V Switchable
Single Phase (120V Amps)888.9A (4 wire)
Single Phase (120-240V Amps)444.4A (4 wire)
Three Phase (208-240V Amps)962A
Three Phase (460-480V Amps)481A
Decibel dB(A) – Full load at 7 m (23ft)67
Fuel Tank Capacity – Litres (Imp Gal)490 (108)
Fuel Consumption at 100% load Litres (Imp Gal)per hour87.3 (19.20)
75% load – Litres (Imp Gal) per hour68.1 (14.98)
50% load – Litres (Imp Gal) per hour48.8 (10.73)
25% load – Litres (Imp Gal) per hour29.7 (6.53)
L x W x H Cm (In) – unit w/o trailer460 x 140 x 210 (181 x 55 x 83)
Net Weight Kg (Lb) – unit w/o trailer5432 (11973)
L x W x H Cm (In) – unit w/ trailer650 x 206 x 279 (256 x 81 x 110)
Net Weight Kg (Lb) -unit w/ trailer7018 (15473)
NEMA Rating3 – Outdoor Use

500 KW Diesel Generator

SpecificationsGenerator – Single
TypeWheeled
Output500 KW
FuelDiesel
RPM1800
Frequency60HZ
Voltage- Three Phase480 – 280/120
Voltage- Single PhaseN/A
Single Phase (120V Amps)1735
Single Phase (120-240V Amps)1500
Three Phase (208-240V Amps)1500
Three Phase (460-480V Amps)750
Decibel dB(A) – Full load at 7 m (23ft)72
Fuel Tank Capacity – Litres (Imp Gal)2650 (700)
Fuel Consumption at 100% load Litres (Imp Gal)per hour136 (35.9)
75% load – Litres (Imp Gal) per hour107 (28.3)
50% load – Litres (Imp Gal) per hour78 (20.5)
25% load – Litres (Imp Gal) per hour40 (11)
L x W x H Cm (In) – unit w/o trailer6096 x 2438 x 2491 (240 x 96 x 102)
Net Weight Kg (Lb) – unit w/o trailer10,247 (22,590)
L x W x H Cm (In) – unit w/ trailer6096 x 2438 x 3810 (240 x 96 x 150)
Net Weight Kg (Lb) -unit w/ trailer13,626 (30,040)
NEMA Rating3 – Outdoor Use

500 – 650 KW Diesel Generator

SpecificationsGenerator – Single
TypeSkidded
Output500 – 650 KW
FuelDiesel
RPM1800
Frequency60HZ
Voltage- Three Phase480 (ONLY)
Voltage- Single PhaseN/A
Single Phase (120V Amps)N/A
Single Phase (120-240V Amps)N/A
Three Phase (208-240V Amps)N/A
Three Phase (460-480V Amps)900A
Decibel dB(A) – Full load at 7 m (23ft)71
Fuel Tank Capacity – Litres (Imp Gal)2270 (500)
Fuel Consumption at 100% load Litres (Imp Gal)per hour128.3 (28.22)
75% load – Litres (Imp Gal) per hour101.1 (22.24)
50% load – Litres (Imp Gal) per hour65.9 (14.50)
25% load – Litres (Imp Gal) per hour40.1 (8.82)
L x W x H Cm (In) – unit w/o skid747 x 244 x 274 (294 x 96 x 108)
Net Weight Kg (Lb) – unit w/o skid10206 (22500)
L x W x H Cm (In) – unit w/ skid747 x 244 x 401 (294 x 96 x 158)
Net Weight Kg (Lb) -unit w/ skid13599 (29980)
NEMA Rating3 – Outdoor Use

600 KW Diesel Generator

SpecificationsGenerator – Single
TypeWheeled
Output600 KW
FuelDiesel
RPM1800
Frequency60HZ
Voltage- Three Phase480 V
Voltage- Single PhaseN/A
Single Phase (120V Amps)N/A
Single Phase (120-240V Amps)N/A
Three Phase (208-240V Amps)N/A
Three Phase (460-480V Amps)820 A
Decibel dB(A) – Full load at 7 m (23ft)72
Fuel Tank Capacity – Litres (Imp Gal)2650 (700)
Fuel Consumption at 100% load Litres (Imp Gal)per hour136 (35.9)
75% load – Litres (Imp Gal) per hour107 (28.3)
50% load – Litres (Imp Gal) per hour78 (20.5)
25% load – Litres (Imp Gal) per hour40 (11)
L x W x H Cm (In) – unit w/o trailer609.6 x 243.84 x 279.4 (240 x 96 x 110)
Net Weight Kg (Lb) – unit w/o trailer10,247 (22,590)
L x W x H Cm (In) – unit w/ trailer914.4 x 243.84 x 396.24 (360 x 96 x 156 )
Net Weight Kg (Lb) -unit w/ trailer13,626 (30,040)
NEMA Rating3 – Outdoor Use

800 – 1000 KW Diesel Generator

SpecificationsGenerator – Single
TypeWheeled
Output800 – 1000 KW
FuelDiesel
RPM1800
Frequency60HZ
Voltage- Three Phase480 (ONLY)
Voltage- Single PhaseN/A
Single Phase (120V Amps)N/A
Single Phase (120-240V Amps)N/A
Three Phase (208-240V Amps)N/A
Three Phase (460-480V Amps)1504A
Decibel dB(A) – Full load at 7 m (23ft)66
Fuel Tank Capacity – Litres (Imp Gal)3787 (833)
Fuel Consumption at 100% load Litres (Imp Gal)per hour295.5 (65.00)
75% load – Litres (Imp Gal) per hour201.8 (44.39)
50% load – Litres (Imp Gal) per hour138.7 (30.51)
25% load – Litres (Imp Gal) per hour77.5 (17.05)
L x W x H Cm (In) – unit w/o trailer1219 x 244 x 290 (480 x 96 x 114)
Net Weight Kg (Lb) – unit w/o trailer17445 (38460)
L x W x H Cm (In) – unit w/ trailer1219 x 244 x 417 (480 x 96 x 164)
Net Weight Kg (Lb) -unit w/ trailer20502 (45200)
NEMA Rating3 – Outdoor Use

1250 – 1500 KW Diesel Generator

SpecificationsGenerator – Single
TypeWheeled
Output1250 – 1500 KW
FuelDiesel
RPM1800
Frequency60HZ
Voltage- Three Phase480 (ONLY)
Voltage- Single PhaseN/A
Single Phase (120V Amps)N/A
Single Phase (120-240V Amps)N/A
Three Phase (208-240V Amps)N/A
Three Phase (460-480V Amps)2258A
Decibel dB(A) – Full load at 7 m (23ft)67
Fuel Tank Capacity – Litres (Imp Gal)3787 (833)
Fuel Consumption at 100% load Litres (Imp Gal)per hour393 (86.45)
75% load – Litres (Imp Gal) per hour298 (65.55)
50% load – Litres (Imp Gal) per hour211 (46.41)
25% load – Litres (Imp Gal) per hour124 (27.28)
L x W x H Cm (In) – unit w/o trailer1219 x 244 x 290 (480 x 96 x 114)
Net Weight Kg (Lb) – unit w/o trailer21083 (46480)
L x W x H Cm (In) – unit w/ trailer1219 x 244 x 417 (480 x 96 x 164)
Net Weight Kg (Lb) -unit w/ trailer24140 (53220)
NEMA Rating3 – Outdoor Use

1750 – 2000 KW Diesel Generator

SpecificationsGenerator – Single
TypeWheeled
Output1750 – 2000 KW
FuelDiesel
RPM1800
Frequency60HZ
Voltage- Three Phase480 (ONLY)
Voltage- Single PhaseN/A
Single Phase (120V Amps)N/A
Single Phase (120-240V Amps)N/A
Three Phase (208-240V Amps)N/A
Three Phase (460-480V Amps)3000A
Decibel dB(A) – Full load at 7 m (23ft)68
Fuel Tank Capacity – Litres (Imp Gal)4546 (1000)
Fuel Consumption at 100% load Litres (Imp Gal)per hour498 (109.54)
75% load – Litres (Imp Gal) per hour378 (83.15)
50% load – Litres (Imp Gal) per hour271 (59.61)
25% load – Litres (Imp Gal) per hour167 (36.73)
L x W x H Cm (In) – unit w/o trailer1219 x 244 x 290 (480 x 96 x 114)
Net Weight Kg (Lb) – unit w/o trailer27669 (61000)
L x W x H Cm (In) – unit w/ trailer1219 x 244 x 417 (480 x 96 x 164)
Net Weight Kg (Lb) -unit w/ trailer31253 (68900)
NEMA Rating3 – Outdoor Use

60 – 75 KW Single Pak Diesel Generator

SpecificationsGenerator – Single
TypeSkidded
Output60 – 75 KW
FuelDiesel
RPM1800
Frequency60HZ
Voltage- Three Phase208 – 480V Switchable
Voltage- Single Phase120 – 277V Switchable
Single Phase (120V Amps)155.5A (4 wire) / 168Ax2 (zigzag)
Single Phase (120-240V Amps)77.8A (4 wire) / 168A (zigzag)
Three Phase (208-240V Amps)168A
Three Phase (460-480V Amps)84A
Decibel dB(A) – Full load at 7 m (23ft)60
Fuel Tank Capacity – Litres (Imp Gal)480 (106)
Fuel Consumption at 100% load Litres (Imp Gal)per hour18.9 (4.16)
75% load – Litres (Imp Gal) per hour13.4 (2.95)
50% load – Litres (Imp Gal) per hour8.9 (1.96)
25% load – Litres (Imp Gal) per hour5.9 (1.30)
L x W x H Cm (In) – unit w/o skid277 x 124 x 180 (109 x 49 x 71)
Net Weight Kg (Lb) – unit w/o skid2127 (4690)
L x W x H Cm (In) – unit w/ skid434 x 183 x 213 (171 x 72 x 84)
Net Weight Kg (Lb) -unit w/ skid3443 (7590)
NEMA Rating3 – Outdoor Use

60 – 75 KW Twin Pak Diesel Generator

SpecificationsGenerator – Twin
TypeSkidded
Output60 – 75 KW
FuelDiesel
RPM1800
Frequency60HZ
Voltage- Three Phase208 – 480V Switchable
Voltage- Single Phase120 – 277V Switchable
Single Phase (120V Amps)155.5A (4 wire) / 168Ax2 (zigzag)
Single Phase (120-240V Amps)77.8A (4 wire) / 168A (zigzag)
Three Phase (208-240V Amps)168A
Three Phase (460-480V Amps)84A
Decibel dB(A) – Full load at 7 m (23ft)60
Fuel Tank Capacity – Litres (Imp Gal)1800L (396)
Fuel Consumption at 100% load Litres (Imp Gal)per hour18.9 (4.16)
75% load – Litres (Imp Gal) per hour13.4 (2.95)
50% load – Litres (Imp Gal) per hour8.9 (1.96)
25% load – Litres (Imp Gal) per hour5.9 (1.30)
L x W x H Cm (In) – unit w/o skid277 x 124 x 180 (109 x 49 x 71)
Net Weight Kg (Lb) – unit w/o skid2127 (4690)
L x W x H Cm (In) – unit w/ skid434 x 183 x 213 (171 x 72 x 84)
Net Weight Kg (Lb) -unit w/ skid3443 (7590)
NEMA Rating3 – Outdoor Use

80 – 100 KW Twin Pak Diesel Generator

SpecificationsGenerator – Twin
TypeSkidded
Output80 – 100 KW
FuelDiesel
RPM1800
Frequency60HZ
Primary Voltage – Three Phase120 / 208
Secondary Voltage – Three Phase277 / 480
Single Phase (120V Amps)N/A
Single Phase (120-240V Amps)12-30A 4 Pole Twist Lock
Three Phase (208-240V Amps)2-30A / 2-60A / 2-100A 4 wire/4 pole Crouse Hines
Three Phase (460-480V Amps)2-30A / 2-60A / 2-100A 3 wire/4 pole Crouse Hines
Decibel dB(A) – Full load at 7 m (23ft)68
Fuel Tank Capacity – Litres (Imp Gal)2270 (500)
Fuel Consumption at 100% load Litres (Imp Gal)per hour25.7(5.7)
75% load – Litres (Imp Gal) per hour21(4.6)
50% load – Litres (Imp Gal) per hour14.7(3.2)
25% load – Litres (Imp Gal) per hour6.3(1.4)
L X W X H m (ft)7.62 X 3.05 X 2.44 (25 X 10 X 8)
(wet) Net Weight Kg (Lb)12,727 Kg (28,000)
NEMA Rating3 – Outdoor Use

80 – 100 KW Twin Pak Combined Fuel Diesel And Natural Gas Generator

SpecificationsGenerator – Twin
TypeSkidded
Output80 – 100 KW
FuelBi-Fuel
RPM1800
Frequency60HZ
Primary Voltage – Three Phase120 / 208v
Secondary Voltage – Three Phase277 / 480v
Voltage – Single PhaseN/A
Single Phase (206-240V Amps)2-30A / 2-60A / 2-100A 4 wire/4 pole Crouse Hines
Three Phase (460-480v Amps)2-30A / 2-60A / 2-100A 3 wire/4 pole Crouse Hines
Decibel dB(A) – Full load at 7 m (23ft)68
Fuel Tank Capacity – Litres (Imp Gal)2270 (500)
Fuel Consumption at 100% load Litres (Imp Gal)per hour25.7(5.7)
 Net Weight Kg (Lb)- unit w/ slkid12,727 Kg (28,000)
NEMA Rating3 – Outdoor Use

175 – 225 KW Skid Type Diesel Generator

SpecificationsGenerator – Single
TypeSkidded
Output175 – 225 KW
FuelDiesel
RPM1800
Frequency60HZ
Primary Voltage – Three Phase480
Secondary Voltage – Three Phase120/208
Single Phase (120V Amps)N/A
Single Phase (120-240V Amps)N/A
Three Phase (120 / 208 Amps Sec)75 Kva transformer
Three Phase (460-480V Amps)N/A
Decibel dB(A) – Full load at 7 m (23ft)68
Fuel Tank Capacity – Litres (Imp Gal)2270 (500)
Fuel Consumption at 100% load Litres (Imp Gal)per hour60 (19.5)
75% load – Litres (Imp Gal) per hour45 (13.2)
50% load – Litres (Imp Gal) per hour40 (8.8)
25% load – Litres (Imp Gal) per hour20 (4.4)
L X W X H m (ft)7.62 x 3.05 x 2.44 (25 x 10 x 8)
(wet) Net Weight Kg (Lb)12,727kg (28,000)
NEMA Rating3 Outdoor Use

175 – 225 KW Wheeled Diesel Generator

SpecificationsGenerator – Single
TypeWheeled
Output175 – 225 KW
FuelDiesel
RPM1800
Frequency60HZ
Voltage- Three Phase208 – 480V Switchable
Voltage- Single Phase120 – 277V Switchable
Single Phase (120V Amps)555.5A (4 wire)
Single Phase (120-240V Amps)277.7A (4 wire)
Three Phase (208-240V Amps)601A
Three Phase (460-480V Amps)301A
Decibel dB(A) – Full load at 7 m (23ft)68
Fuel Tank Capacity – Litres (Imp Gal)460 (101)
Fuel Consumption at 100% load Litres (Imp Gal)per hour55.8 (12.27)
75% load – Litres (Imp Gal) per hour41.2 (9.06)
50% load – Litres (Imp Gal) per hour28.5 (6.27)
25% load – Litres (Imp Gal) per hour16.6 (3.65)
L x W x H Cm (In) – unit w/o trailer375 x 140 x 180 (146 x 55 x 71)
Net Weight Kg (Lb) – unit w/o trailer4220 (9305)
L x W x H Cm (In) – unit w/ trailer544 x 198 x 267 (214 x 78 x 105)
Net Weight Kg (Lb) -unit w/ trailer6398 (14105)
NEMA Rating3 Outdoor Use

300 – 425 KW Single Pak Diesel Generator

SpecificationsGenerator – Single
TypeWheeled
Output300 – 425 KW
FuelDiesel
RPM1800
Frequency60HZ
Primary Voltage- Three Phase480V
Secondary Voltage- Three Phase208V
Voltage – Single PhaseNA
Single Phase (Amps)N/A
Three Phase (480V Amps)639.45A
Three Phase (208Amps)1475A
Decibel dB(A) – Full load at 7 m (23ft)67
Fuel Tank Capacity – Litres (Imp Gal)2270(500)
Fuel Consumption at 100% load Litres (Imp Gal)per hour108.2(23.81)
75% load – Litres (Imp Gal) per hour80.6(17.74)
50% load – Litres (Imp Gal) per hour56.4(12.41)
25% load – Litres (Imp Gal) per hour33.7(7.41)
L x W x H Cm (In) – unit w/o skid762 x 244 x 335 (300 x 96 x 132)
Net Weight Kg (Lb) – unit w/o skid13,608 (30,000)
NEMA Rating3 – Outdoor Use

80 – 100 KW Natural Gas / Propane Generator

SpecificationsGenerator – Single
TypeSkidded
Output80 – 100 KW
FuelNatural Gas / Propane Conversion
RPM1800
Frequency60HZ
Voltage- Three Phase480 (ONLY)
Three Phase (460-480V Amps)150
Decibel dB(A) – Full load at 7 m (23ft)63
100% load BTU/hr ft3/hr ft3/min1918825.0 2019.8 33.7
75% load BTU/hr ft3/hr ft3/min1398764.4 1472.4 24.5
50% load BTU/hr ft3/hr ft3/min932509.6 981.6 16.4
25% load BTU/hr ft3/hr ft3/min457112.8 481.25 8.25
(wet) Net Weight Kg (Lb)10,455 (23,000)
NEMA Rating3 – Outdoor Use

130 – 150 KW Natural Gas / Propane Generator

SpecificationsGenerator – Single
TypeSkidded
Output130 – 150 KW
FuelNatural Gas / Propane Conversion
RPM1800
Frequency60HZ
Voltage- Three Phase480 (ONLY)
Voltage- Single PhaseN/A
Single Phase (120V Amps)N/A
Single Phase (120-240V Amps)N/A
Three Phase (208-240V Amps)N/A
Three Phase (460-480V Amps)225
Decibel dB(A) – Full load at 7 m (23ft)63
100% load BTU/hr ft3/hr ft3/min1918825.0 2019.8 33.7
75% load BTU/hr ft3/hr ft3/min1398764.4 1472.4 24.5
50% load BTU/hr ft3/hr ft3/min932509.6 981.6 16.4
25% load BTU/hr ft3/hr ft3/min457112.8 481.25 8.25
L x W x H Cm (In) – Skid Type Unit762 x 244 x 310 (300 x 96 x 122)
Net Weight Kg (Lb) – Skid Type Unit10,455 (23,000)
NEMA Rating3 – Outdoor Use

190 – 240 KW Natural Gas / Propane Generator

SpecificationsGenerator – Single
TypeSkidded
Output190 – 240 KW
FuelNatual Gas / Propane Conversion
RPM1800
Frequency60HZ
Volatge- Three Phase480 (ONLY)
Volatge- Single PhaseN/A
Single Phase (120V Amps)N/A
Single Phase (120-240V Amps)N/A
Three Phase (208-240V Amps)N/A
Three Phase (460-480V Amps)360
Decibel dB(A) – Full load at 7 m (23ft)64
100% load BTU/hr ft3/hr ft3/min2,398 39.9
75% load BTU/hr ft3/hr ft3/min1,912 31.8
50% load BTU/hr ft3/hr ft3/min1,418 23.6
L x W x H Cm (In) – Skid Type Unit762 x 244 x 310 (300 x 96 x 122)
Net Weight Kg (Lb) – Skid Type Unit13,200 (29,000)
NEMA Rating3 – Outdoor Use

300 – 400 KW Natural Gas Generator

SpecificationsGenerator – Single
TypeSkidded
Output300-400 KW
FuelNatural Gas
RPM1800
Frequency60HZ
Voltage- Three Phase480 (ONLY)
Voltage- Single PhaseN/A
Single Phase (120V Amps)N/A
Single Phase (120-240V Amps)N/A
Three Phase (208-240V Amps)N/A
Three Phase (460-480V Amps)600
Decibel dB(A) – Full load at 7 m (23ft)64
100% load BTU/hr ft3/hr ft3/min4,472 74.5
75% load BTU/hr ft3/hr ft3/min3,576 59.6
50% load BTU/hr ft3/hr ft3/min2,702 45
L x W x H Cm (In) – Skid Type Unit1372 x 305 x 366 (540 x 120 x 144)
Net Weight Kg (Lb) – Skid Type Unit22,000 (49,000)
NEMA Rating3 – Outdoor Use

Dependable Power. Proven Performance

Request A Quote